Installation precautions for leaky cables

Update:May 10,2022
Summary:1. The two leaky cables must be installed in parallel with a distance of 0.3m to 1.0m (0.5m is recommended). 2. The buried depth of the leaking cable ...
1. The two leaky cables must be installed in parallel with a distance of 0.3m to 1.0m (0.5m is recommended).
2. The buried depth of the leaking cable is 0~10 cm (it is recommended to bury it as shallowly as possible).
3. The power lines, signal lines and leaking cables should not be placed close to each other, nor should they be installed in the same PVC pipe, and the distance between them should be greater than 50 cm.
4. When burying the leaking cables, PVC pipes must be worn to prevent them from being damaged.
5. The frequencies of the two sets of leaky cable hosts installed adjacent to each other should be staggered.
6. The buried location of the leaking cable must be more than 5 meters away from the roadway and more than 3 meters away from the sidewalk.